- Anchorage
- The fixings and embedment that hold a joint system to the structure and transfer load into it.
- Backer rod
- A compressible foam rod placed in a joint to control sealant depth and provide a bond-breaker.
- Bellows
- A flexible convoluted seal (rubber, fabric or metal) used mainly in pipe and duct expansion joints.
- Blockout
- A recess formed in the slab edge to receive and anchor a floor joint frame flush with the finished surface.
- Centre plate (cover plate)
- The plate that spans the joint gap in a metal cover system, sliding or self-centring as the structure moves.
- Coefficient of thermal expansion (α)
- How much a material expands per degree of temperature change — e.g. ~11×10−6/°C for concrete. Drives thermal movement.
- Compression seal
- A pre-compressed elastomeric profile wedged into a joint; it seals by remaining in compression.
- Control (contraction) joint
- A planned line of weakness that forces concrete to crack in a chosen location as it shrinks. Not a moving joint.
- Deflection
- Vertical movement of a floor, deck or beam under load — one of the movements a joint may need to accommodate.
- Elastomer
- A rubber-like polymer (EPDM, neoprene, silicone, TPV) that flexes and returns to shape; the sealing element of most joints.
- EPDM
- Ethylene propylene diene monomer — the workhorse building-joint elastomer, with excellent weather, UV and ozone resistance.
- Fire barrier
- A joint system component that maintains the fire-resistance rating of a wall or floor across the joint (e.g. 2–4 hr).
- Finger joint
- A bridge deck joint with interlocking steel fingers for very large movement. A structural, not architectural, type.
- Gland
- The elastomeric sealing element (often EPDM) retained by the frame in a watertight or deck joint.
- Intumescent
- A material that expands when heated to seal a gap against fire and smoke; used in fire-rated joints.
- Movement class
- A system’s rated movement capability, classified by ASTM E1399 as Category I–IV (IV is highest).
- Neoprene (CR)
- Chloroprene rubber — a general-purpose sealing elastomer with moderate oil and weather resistance.
- Nosing
- The edge material (often elastomeric concrete) protecting the joint arris against traffic and impact.
- Plaza deck / split slab
- A landscaped or trafficked deck over occupied space, requiring a watertight, often insulated, joint.
- Seismic joint
- A high-movement, multi-directional joint that separates building sections to absorb earthquake movement.
- Self-centring
- A mechanism (spring or bar) that returns a cover plate to its central position after movement.
- Shore hardness
- A measure of elastomer hardness (e.g. Shore A 65 for a joint gasket).
- Strip seal
- A bridge deck joint with a single elastomeric strip in steel edge rails, for moderate movement.
- Thermal movement
- Expansion and contraction of a structure with temperature; the most common driver of joint design.
- TPV / TPE
- Thermoplastic vulcanisate / elastomer — recyclable, weldable seal materials used in floor and roof joints.
- UL 2079
- The standard fire test for building joint systems, giving hourly ratings (1–4 hr).
- Vapour barrier
- A membrane under a floor joint cover that resists moisture and vapour migration.
- Watertight
- A joint that resists water passage, verified by test (fire-hose or pressure) — essential for decks and roofs.
- Wind sway
- Lateral, cyclic movement of a tall building under wind load, felt at facade and seismic joints.